Their function

The AIRTEC central ejectors function according to the Venturi principle. Compressed air with 4 to 6 bar flows through a protective filter in the compressed air supply port (1.1) into the ejector creating a vacuum in the mixing chamber (C). The vacuum line is evacuated via connection (2) and another protective filter.
A check valve (D) between the mixing chamber (C) and connection (2) as well as in connection (1.2) seal off the vacuum system to the atmosphere so that in the event of the compressed air supply being interrupted in an airtight vacuum system, the vacuum remains unaffected.
To this end, the production series HV-SA with flange-mounted electronic vacuum switches has a parts control or an electronically controlled saver circuit with parts control. With an integrated mechanical-pneumatic vacuum regulator, the production series HV-P is able to carry out an automatic saving function. Electronic vacuum switches also enable a parts control.
An air blast in connection (1.2), which also has a protective filter fitted against the infiltration of dirt, quickly relieves the vacuum and in the process, also cleans the protective filter in (2).
All ejector models can also be delivered with integrated solenoid valves, in the form of a compact unit. A fully pneumatic ejector control system with a pneumatic vacuum switch is possible on request.




  Results 1 - 12 of 12 1 

Item #

Air Consumption

Function

Weight

Size of Orifice

Noise Level at 4 bar

HV-P-150 150 nL/min
0.1520
Cv
Vacuum, air-saving automatic function and blow off, without vacuum switch 0.475 kg 1.6 mm 83 dB
HV-P-300 300 nL/min
0.3050
Cv
Vacuum, air-saving automatic function and blow off, without vacuum switch 0.515 kg 2.5 mm 83 dB
HV-P-500 500 nL/min
0.5080
Cv
Vacuum, air-saving automatic function and blow off, without vacuum switch 0.506 kg 3.0 mm 80 dB
HV-PVP-150 150 nL/min
0.1520
Cv
Vacuum, air-saving automatic and blow off function with additional control system for the air saving device and parts control N/A 1.6 mm 83 dB
HV-PVP-300 300 nL/min
0.3050
Cv
Vacuum, air-saving automatic and blow off function with additional control system for the air saving device and parts control N/A 2.5 mm 83 dB
HV-PVP-500 500 nL/min
0.5080
Cv
Vacuum, air-saving automatic and blow off function with additional control system for the air saving device and parts control N/A 3.0 mm 80 dB
HV-PSU-150 150 nL/min
0.1520
Cv
Vacuum, air-saving automatic function, blow off inter ruption 0.3 s, without vacuum switch N/A 1.6 mm 83 dB
HV-PSU-300 300 nL/min
0.3050
Cv
Vacuum, air-saving automatic function, blow off inter ruption 0.3 s, without vacuum switch N/A 2.5 mm 83 dB
HV-PSU-500 500 nL/min
0.5080
Cv
Vacuum, air-saving automatic function, blow off inter ruption 0.3 s, without vacuum switch N/A 3.0 mm 80 dB
HV-PSUVP-150 150 nL/min
0.1520
Cv
Vacuum, air-saving automatic function, blow off inter ruption 0.3 s, with adjustable vacuum sensor for parts control and air saving device N/A 1.6 mm 83 dB
HV-PSUVP-300 300 nL/min
0.3050
Cv
Vacuum, air-saving automatic function, blow off inter ruption 0.3 s, with adjustable vacuum sensor for parts control and air saving device N/A 2.5 mm 83 dB
HV-PSUVP-500 500 nL/min
0.5080
Cv
Vacuum, air-saving automatic function, blow off inter ruption 0.3 s, with adjustable vacuum sensor for parts control and air saving device N/A 3.0 mm 80 dB
  Results 1 - 12 of 12 1 